UIS Commands page (click for more info) File Import page (click for more info) System Settings page (click for more info) Input Items page (click for more info) Meters/Owners page (click for more info) Neural Networks page (click for more info) Advanced page (click for more info) General Information (click for more info) Transaction Logging (click for more info) Device Security (click for more info)

Configuring the ELF Device

The Device page is used to configure general information about the device such as the ELF device name, description, transaction logging, and device security.

ELF Device page

ELF Device page

The properties for each section of this page are described below.

Device Settings

Parameter Description

Device ID

The unique identifier of an instance for this device. This free-form name must be unique in the DDS and the FAC. That is, it must be a name not used by any other communication device, import/export device, remote device, or facility.

CygNet naming standards for device ID are as follows:

Component Valid Character Set Limits

Device ID

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z (uppercase)

0 1 2 3 4 5 6 7 8 9

dash (-), underscore (_), and tilde (~).

Note: Tilde (~) is a valid character for both devices and facilities, but its use is not recommended.

20 character maximum

No spaces

Description

A free-form description of the device. 32 character maximum.

Enable Device

Select whether to enable or disable the device. The default setting is disabled. If an invalid configuration is detected, the device will automatically be disabled. The device can be re-enabled after the invalid configuration is fixed.

Transaction Logging

When an ELF operation (import, training, forecasting, or variance analysis) is performed, a DDS transaction is generated detailing the results of the operation. This transaction history can be stored in the DDS or it can be written to file. If written to the file system, one log file is created for each ELF transaction. Log file names will include the corresponding processed file name, a timestamp, and a .log extension.

Parameter Description

Max Log Records

The maximum number of transaction history records that can be maintained for the device. Each UIS command executed by the device will generate a single transaction log. If the device is setup for active monitoring, one transaction will be created whenever a new file is detected. If multiple files are detected at the same time, it will still result in one transaction.

View Transaction Log

Click to view transaction and status log entries.

See Transaction Log below.

Device Security

The security fields define the application and event that controls which user(s) can perform the import. See Component-Level Security - Text Import Device for more information about component-level security.

Parameter Description

Application

Defines the ACS security application name used to validate the users of this device. See Applications, Events, Permissions.

Event

Defines the ACS security event used to validate users of this device. Click to select the security event. See Applications, Events, Permissions.

Transaction Log

Click View Transaction Log and the desired log type to see the transaction record.

Transaction record

Transaction record

The properties on the Training Log dialog box are described below.

Parameter Description

Transaction

Select the transaction you want to view.

Status

The status of the operation: Succeeded or Failed.

Log

The main part of the window displays information about the operation, including: start and end time, duration, warnings, messages, and errors.

Refresh

Click Refresh to refresh the log.

Close

Click Close to close the Transaction Log dialog box.

Back to top